ICH Q7 guidelines define Good Manufacturing Practice for active pharmaceutical ingredients (APIs). Published by ICH in November 2000 (CPMP/ICH/4106/00) and adopted in Europe as the basis of Part II of EudraLex Volume 4, ICH Q7 remains the benchmark that authorities such as EMA and FDA use when inspecting API manufacturers. In this article we look at what ICH Q7 actually covers, how it connects to EU GMP and PIC/S, where GMP obligations begin along an API synthesis, and the points inspectors check most often.
What the ICH Q7 guidelines are and who they apply to
ICH Q7 — the "Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients" — sets GMP requirements for manufacturing APIs for human medicinal products, including APIs for clinical trials (Section 19). It applies to manufacturing by chemical synthesis, extraction, classical fermentation and cell culture/biotech fermentation, as well as to repackaging, relabelling and distribution activities performed by agents, brokers and traders (Section 17).
The underlying principle is the same as for finished-product GMP: every manufacturer must ensure the API has the quality and purity it claims, through an effective quality management system, qualified personnel, suitable facilities and documentation that keeps every batch traceable. What changes is the perimeter: GMP does not cover the whole synthesis from the first reagent, but kicks in at a precise point of the process — and this is where ICH Q7 introduces the single most important concept of the entire guideline.
API Starting Material: where GMP begins
ICH Q7 defines the API Starting Material as a raw material, intermediate or API that is used in the production of an API and is incorporated as a significant structural fragment into the structure of the active substance. From that point onwards the guideline applies, with increasing rigour as the process moves towards the final API.
Table 1 of ICH Q7 turns this principle into practice for each manufacturing type:
| Type of manufacturing | Typical steps | Application of ICH Q7 |
|---|---|---|
| Chemical synthesis | Production of the starting material → introduction into the process → intermediates → isolation and purification → physical processing and packaging | From the introduction of the API Starting Material into the process |
| Extraction (e.g. from plants) | Collection → cutting and initial extraction → introduction of the starting material → isolation and purification → packaging | From the introduction of the API Starting Material |
| Biotechnology (cell culture/fermentation) | Master and working cell banks → maintenance of the working cell bank → cell culture/fermentation → isolation and purification → packaging | From maintenance of the working cell bank |
| "Classical" fermentation | Maintenance of the cell bank → introduction of the cells into fermentation → fermentation → isolation and purification → packaging | From the introduction of the cells into fermentation |
Choosing and justifying the API Starting Material remains one of the most contested points in dossiers and inspections: a designation set too far "downstream" artificially shrinks the GMP perimeter, and the ICH Q7 Q&A document published by EMA stresses precisely the need to apply increasing rigour from the earliest covered steps through to the final stages.
If you work with APIs and GMP you know it: guidelines are read once but applied every day. The Pragmatic GMP is GuideGxP's free weekly newsletter that turns requirements like those of ICH Q7 into operational decisions you can defend in an audit. Subscribe here.
The structure of the guideline: 20 sections
ICH Q7 is organised into 20 sections that mirror, with the necessary adaptations, the chapters of finished-product GMP:
- Introduction (objective and scope)
- Quality management
- Personnel
- Buildings and facilities
- Process equipment
- Documentation and records
- Materials management
- Production and in-process controls
- Packaging and identification labelling of APIs and intermediates
- Storage and distribution
- Laboratory controls
- Validation
- Change control
- Rejection and re-use of materials
- Complaints and recalls
- Contract manufacturers (including laboratories)
- Agents, brokers, traders, distributors, repackers and relabellers
- Specific guidance for APIs manufactured by cell culture/fermentation
- APIs for use in clinical trials
- Glossary
Two sections deserve special attention. Section 14 allows practices typical of the API world and absent from finished products, such as reprocessing and — under strict conditions — reworking and solvent recovery. Section 17 extends GMP obligations to commercial players that manufacture nothing but handle APIs: an area that supply-chain and Written Confirmation inspections have made central.
What falls outside the scope
ICH Q7 expressly excludes:
- vaccines, whole cells, whole blood and plasma and their derivatives (plasma fractionation), and gene therapy APIs;
- medicinal gases, bulk-packaged drug products and aspects specific to radiopharmaceuticals;
- the sterilisation and aseptic processing steps of sterile APIs: ICH Q7 covers the process only up to the point immediately prior to sterilisation, which falls under sterile-product GMP (in Europe, Annex 1).
Beware of the most common misunderstanding: "excluded from ICH Q7" does not mean "no GMP". Steps before the API Starting Material and cell substrates remain subject to appropriate control expectations, even if outside the guideline's formal perimeter.
ICH Q7, EudraLex Part II and PIC/S: one text, three frameworks
In Europe ICH Q7 is not an "optional" reference: its content was adopted as Part II of EudraLex Volume 4 ("Basic Requirements for Active Substances used as Starting Materials", August 2014 version), which is the yardstick for EU/EEA authority inspections of active-substance manufacturers. PIC/S did the same with Part II of its own GMP Guide (now PE 009-18, in force since 24 September 2026), used by non-EEA PIC/S authorities. For exporters this alignment is good news: a site compliant with ICH Q7 speaks the same language as EMA, FDA (which adopted Q7 as guidance for industry) and PIC/S authorities.
GuideGxP recommendation
If you work in QA or API manufacturing, use ICH Q7 as an operational document, not as background reading. Three concrete actions: (1) check that the API Starting Material designation of every process is justified in writing and consistent with the registration dossier — it is one of the first requests in an inspection; (2) map your SOPs against the guideline's 20 sections and surface the gaps (change control, reprocessing and supplier management are the most frequent); (3) build the EMA/ICH Q&A document into your personnel training package, because that is where the interpretations used by inspectors live.
To go beyond Q7: the GuideGxP guide Quality Guidelines ICH Q: what is actually applicable, and readiness for the new Q1 reconstructs, sentence by sentence, where every text of the ICH Q series is binding and where it is not — with a ready-to-use Excel/Word toolkit.