Skip to product information
1 of 7

Pipettes, dilutions, filtration, centrifuges and weighing: selection, use and documented in-use checks.

  • PDF guide
  • 16 editable tools
  • Future releases included
Regular price €179,00 EUR
Regular price Sale price €179,00 EUR
Sale Sold out
Taxes included. Digital product – immediate access after payment.
Language of the purchased files

Choose the Italian or English edition. The website language does not change the file language.

Download after payment · No shipping

View full details

Contents & tools

Inside the guide

Explore the programme, examples and included resources before choosing.

First edition · v1.0 · regulatory verification 21/11/2026

RPM is not RCF, minimum weight is not the balance's Min, ISO 8655 is not a GMP requirement: sample preparation governed with the source next to every value.

A quality and technical guide for those who prepare samples and solutions and govern liquid handling and weighing instruments in the GMP QC laboratory: preparation, dilution and filtration, pipettes and pipetting technique, dispensers, burettes and liquid handlers, centrifuges, mixing and sonication, balances and analytical weighing. 18 chapters in five parts and 6 appendices, 179 pages in the Italian edition and 184 in the English one, and 16 editable tools in Word and Excel, for €179.

179 pages (ITA) · 184 (ENG) · A4 PDF18 chapters in five parts + 6 appendices16 tools: 6 Word + 10 Excel90 sources in the matrix106 tracked decisionsDigital product: download after payment
One language per purchase, chosen by the variant. The ITA - Italiano variant gives you the PDF guide and the 16 tools in Italian; the ENG - English variant gives them in English. Both editions have the same structure, the same tools and the same codes LH-TK-01…16. There are no files in French, German or Spanish.

The decisions it helps you make

Every chapter starts from a laboratory operation and takes it to the documented decision: who decides, on what basis and where it is recorded. 106 decision codes, collected in Appendix E.

Workflow, records and labels
Which texts govern preparation, who is responsible for what, which data each step must leave behind and how the validity of prepared solutions and samples is set. Changing the preparation is a change to be approved.
Chapter 1 · LH-TK-01
Serial dilutions
Scheme, glassware and pipette for every step, error propagation with the common systematic error that does not average out, review of calculations and the mistakes no uncertainty covers.
Chapter 2 · LH-TK-02
Extraction and recovery
What recovery measures and what it does not, matrix and reproducibility, preparation variables as method parameters, a recovery study with criteria fixed before the data.
Chapter 3 · LH-TK-03
Filter, discard volume and concentration
Filter suitability tested with the method sample, adsorption and discard volume from the study, supplier changes under the same code, mass balance of evaporation.
Chapter 4 · LH-TK-04
Pipette and tips for the intended use
Air or positive displacement, range and nominal volume, single or multichannel, manual or electronic, permitted pipette + tip combinations with the evidence behind them.
Chapters 5, 7 and 8 · LH-TK-05
Pipetting technique
Forward or reverse technique assigned per liquid, pre-wetting, angle, immersion, rhythm and acclimatisation, volatile, viscous and foaming liquids, training and competence checks.
Chapter 6 · LH-TK-06
Pipette fleet and intermediate checks
Status and due dates, gravimetric check with mass-to-volume conversion, channel-by-channel check of multichannel pipettes, release after service, out-of-criterion results handled on the user side.
Chapters 7 and 9 · LH-TK-07, LH-TK-08
Dispensers and burettes
Compatibility with the solvent, priming and air, tightness, reading and second check in manual titration, gravimetric in-use check and release after maintenance.
Chapters 10 and 11 · LH-TK-09
Liquid handler
URS and qualification as a system (hardware, software, programs, liquid classes, method), volumetric checks per channel and per program, program changes under change control.
Chapter 12 · LH-TK-09, LH-TK-10
Centrifugation
RCF and reference radius written in the method, a sheet per rotor, speed, temperature and time checks with calibrated test instruments, rotor register, faults and release.
Chapters 13 and 14 · LH-TK-11, LH-TK-12
Mixing and sonication
Explicit parameters for vortex mixers, orbital shakers and homogenisers; bath or probe, final temperature, position in the bath, volume made up to the mark while warm, and evaporation.
Chapters 15 and 16 · LH-TK-13
Balance, minimum weight and weighing
Capacity, scale interval, verification scale interval and minimum weight as distinct quantities, minimum weight for use from repeatability data, weighing technique, static, printouts and in-use checks with their trend.
Chapters 17 and 18 · LH-TK-14, LH-TK-15, LH-TK-16

The problems it tackles

Statements that circulate as "requirements" although the sources say something different. For each one the guide gives the document, clause, nature and jurisdiction.

"RPM and RCF are the same thing: the set speed applies to every rotor." Relative centrifugal force depends on the square of the speed and on the radius (RCF = ω²r/g_n, where g_n is the conventional value in the VIM): at the same rpm different rotors give different RCFs. The method prescribes the RCF, reference radius, time and temperature, and the rpm are recalculated for each rotor. In Case D the same rpm on a larger rotor give 5152 × g instead of 3000 × g (Chapters 13 and 14).

"The minimum weight is a fixed number of balance scale intervals." The minimum weight for use is the smallest net mass that, on that balance at the place of use, meets the user's accuracy requirement: it is derived from the measured repeatability (m_min = k·s/U_rel,req, EURAMET cg-18, Appendix G) and from any safety factor chosen by the user. It does not coincide with the legal-metrology "Min" and it is not demonstrated with the tare (Chapters 17 and 18).

"Pre-wetting is always done a fixed number of times." The five pre-wetting cycles of DKD-R 8-1 are a calibration rule, not a rule for use: when and how many times to pre-wet in routine work is written in the laboratory's SOP, with its justification and for the method's liquid (Chapter 6).

"ISO 8655 is a GMP requirement." It is a paid technical standard that binds the laboratory only if the laboratory adopts it in its own procedures: a maximum permissible error taken from the standard does not on its own become the criterion for using a pipette. EU GMP requires instruments to be calibrated and checked at defined intervals by appropriate methods (EudraLex Volume 4, Chapter 3, point 3.41); criteria, frequencies and replicates are set by the user (Chapters 5 and 9).

"OMCL documents apply to every laboratory." The guidance of the OMCL Network (EDQM), from the Core document to the annexes on piston-operated volumetric apparatus and on balances, is written for Official Medicines Control Laboratories; other laboratories may use it on a voluntary basis, justifying the choice, and its examples of frequencies and replicates remain examples (Chapters 9 and 17).

"Legal verification replaces GMP calibration." Three regimes coexist for a QC laboratory balance: legal metrology (conformity when put into service under Directive 2014/31/EU and, where national law requires it, periodic verification), the calibration required by GMP and the in-use checks set by the laboratory. None replaces the others, and the periodicity of legal verification is not a GMP calibration interval (Chapter 17).

"WHO TRS 957 is the current version of the good practices for QC laboratories." The current text is TRS 1052, Annex 4 (26/04/2024), which revised TRS 957, Annex 1 (2010): it is international guidance, used as a reference and not as a requirement in the EU, Italy, the United Kingdom or the United States. The sentence on balances checked daily and requalified annually is in TRS 957, as an example of a procedure (Chapters 1 and 17).

The guide
18 chapters in five parts, named after the five themes of the Liquid Handling & Sample Preparation hub, and 6 appendices. Every operation follows the same path: operation → requirement → force of the source → what it requires and what it leaves open → documented decision → in-use check and evidence → inspector question → tool. Four status labels, one for adopted texts not yet applicable, and seven nature labels tell you what each source is worth and in which jurisdiction.
The toolkit
16 editable tools: 10 Excel workbooks and 6 Word templates, each as a clean template and as a filled-in example copy. The Excel workbooks have README, PARAMETERS, LISTS, TEST and SOURCES sheets, "Outcome" and "Reason" columns, no macros and no external links, and return only "Comparison with the entered criteria" or "Assessment required".
Melvardi Pharma S.r.l.
One fictitious company for the whole book and toolkit: the chemical QC laboratory of Melvardi Pharma, with 163 items of equipment. Five integrated cases: a syringe filter changed under the same code, with adsorption and low results on nine batches (Case A); a 1000 µL pipette outside its criterion at the intermediate check, with 52 preparations to examine (B); a liquid handler program changed without change control (C); a replaced rotor run at the same rpm, 5152 × g instead of 3000 × g in 14 runs (D); a 6.84 mg weighing below the derived minimum weight (E).
Regulatory status verified as of 21/11/2026

The guide describes the regulatory and technical framework as of 21/11/2026; documents published or amended after this date are not considered. Every source carries a status label (current, draft, in development, superseded) and a nature label, with the jurisdiction where it applies; adopted texts that apply in the future carry the date from which they apply. The points that most often change the reading:

  • EudraLex Volume 4: Chapters 3, 4 and 6, Annex 11 (2011) and Annex 15 (2015) are current, on the basis of Directive (EU) 2017/1572, applicable since 31/01/2022. ICH Q2(R2) and Q14 have been in force in the EU since 14/06/2024; PIC/S PE 009-18 has been in force since 24/09/2026 and PI 006-4 since 01/10/2026.
  • EU drafts: the 2025 revisions of Chapter 4, Annex 11 and Chapter 1 and the new Annex 22 are drafts, not requirements; for Annex 15 only a concept paper exists; the revision of Chapter 3 is in development, with a Q4 2028 target in the work plan.
  • WHO and the OMCL Network: the current WHO text is TRS 1052, Annex 4 (26/04/2024), which superseded TRS 957, Annex 1. The OMCL documents Core R7, Annex 6 R3 (piston-operated volumetric apparatus) and Annex 8 R12 (balances) are guidance for the OMCL Network; no OMCL documents appear to exist on centrifuges and liquid handlers.
  • Pharmacopoeias and the USA: Ph. Eur. 12.3 has been current since 01/07/2026; Issues 13.1 (with the revised chapter 2.1.7 on balances) and 13.2 are adopted and apply from 01/01/2027 and from 01/04/2027. USP–NF 2026, Issue 5, has been official since 01/10/2026; for 21 CFR 210 and 211 the eCFR text as of 19/11/2026 applies.
  • Technical standards and legal metrology: EURAMET cg-18 v4.0 and cg-19 v4.1 are current; ISO 8655 and IEC 61010-2-020:2026 (the 2016 edition has been superseded since 02/09/2026) are paid standards and the guide gives only their title, edition and status. OIML R 76-1:2006 is current, with a revision in development; the Omnibus IV proposal is a draft.

Updates included. Appendix F lists the events that trigger re-verification of the guide: applicability of Ph. Eur. 13.1 and 13.2, USP–NF 2026 Issue 6, final texts of the 2025 drafts of Chapter 4, Annex 11 and Chapter 1 and of the new Annex 22, the draft of Annex 15, the vote on the Omnibus IV proposal, the revisions of OIML R 76 and of Chapter 3, and the list of OMCL Network documents. When the texts change, you receive the revised guide and toolkit at no extra cost. The guide does not announce release dates for its own revisions: the revision on sale is shown on this page.

The 16 tools, in five groups

One folder for each part of the book, with the exact titles of the English edition. No operational value is preloaded: tolerances and use criteria, frequencies of checks and intermediate checks, numbers of replicates, recovery windows and discard volumes, validity of solutions, RCF, times and temperatures, safety factor and accuracy requirement for the minimum weight, control chart limits and acceptance criteria remain <to be defined>, with the decision code.

01_Preparation_Dilution_Filtration · Preparation, Dilution & Filtration
EXCEL
LH-TK-01 · Sample and solution preparation register with traceability and expiry dates
Reagents, solutions, standards and prepared samples: materials and lots, masses, volumes, filter, centrifuge and sonication, label contents, validity and expiry; extracts the preparations made with one instrument over a period.
EXCEL
LH-TK-02 · Serial dilution calculator and volumetric error propagation
Overall factor and final concentration over up to six steps, propagation of the uncertainties entered with correlation when the same pipette recurs, dominant contribution, plausibility, gravimetric check of one step.
WORD
LH-TK-03 · Extraction recovery study protocol and report
Protocol and report with design, criteria and tests fixed before the data; separates the recovery of one step from method accuracy and links the outcome to change control.
EXCEL
LH-TK-04 · Filter study: adsorption, discard volume and recovery
Recovery by successive filtrate fractions, discard volume as the first fraction within the window entered, comparison of filter lots, receipt check, real concentration factor from the mass balance.
02_Pipettes_Technique · Pipettes & Pipetting Technique
EXCEL
LH-TK-05 · URS and selection matrix for pipettes and tips
From the method's liquids and volumes to a URS: candidate pipettes requirement by requirement, permitted pipette + tip combinations with their evidence, acceptance tests before first use.
WORD
LH-TK-06 · SOP "Pipetting technique and challenging liquids" with training record
Model SOP on forward and reverse technique, pre-wetting, acclimatisation and challenging liquids, with a technique assignment table per liquid and a training record with a practical test.
EXCEL
LH-TK-07 · Pipette fleet register: status, due dates and gravimetric intermediate checks
Status, location and due dates of the fleet; gravimetric check with mass-to-volume conversion, systematic and random error, per-channel check of multichannel pipettes, service, releases and out-of-criterion results.
WORD
LH-TK-08 · Release form after cleaning, maintenance or service and start of the impact assessment
One form for two events: release after cleaning, maintenance, repair or relocation, and an out-of-criterion result with segregation, deviation, the period to examine and hand-over to the impact assessment.
03_Dispensing_Automation · Dispensing & Automated Handling
EXCEL
LH-TK-09 · Gravimetric in-use check of dispensers, burettes and channels
Gravimetric in-use check of bottle-top dispensers, glass and digital burettes, channels of multichannel pipettes and liquid handlers, per channel and per program version, with the test liquid density and its source.
WORD
LH-TK-10 · URS and qualification protocol for the automated liquid handler
URS and DQ, IQ, OQ and PQ protocol for the liquid handler as a system: operating limits and worst cases, testing with the real method and liquid, approved programs, change rules and requalification.
04_Centrifugation_Mixing · Centrifugation & Mixing
EXCEL
LH-TK-11 · RPM↔RCF calculator and method centrifugation parameter sheet
RCF ↔ rpm conversion per rotor with the declared reference radius, the method centrifugation parameter sheet and a check of runs against the rpm set and the rotor recorded.
WORD
LH-TK-12 · Centrifuge qualification protocol and rotor register
IQ, OQ with speed, temperature and time measured with calibrated test instruments, PQ, periodic checks and requalification; rotor register, faults and release after service.
EXCEL
LH-TK-13 · Mixing and sonication parameter sheet with temperature control
Explicit parameters for vortex mixers, orbital shakers, homogenisers and sonication; temperature rise in the adiabatic limit, final temperature against the limit entered, volume made up while warm, bath map.
05_Weighing · Weighing & Balance Selection
EXCEL
LH-TK-14 · Balance selector and minimum weight calculation from the user's repeatability data
Candidate balances against the weighing requirements; repeatability test at the place of use and minimum weight for use m_min = k·s/U_rel,req with the chosen safety factor; net mass check; the three states of the balance.
WORD
LH-TK-15 · SOP "Analytical weighing" with in-use checks
Model SOP: pre-use checks, environment and static, direct weighing, weighing by difference and quantitative transfer, net minimum weight, printouts and original records, repeated weighings, user-side out-of-criterion handling.
EXCEL
LH-TK-16 · Balance in-use check register and trends
Levelling, test weight, repeatability and minimum weight verification compared with the criteria entered; control chart with limits and reaction rules chosen by the user; legal metrology, calibration and in-use check due dates.

In the ITA - Italiano variant the same 16 tools carry the titles of the Italian edition and the same codes LH-TK-01…16. Every tool also comes as a filled-in example copy on the Melvardi Pharma case, in the 06_Examples folder.

Ready to use tomorrow morning

The situationWhat you use
A syringe filter with the same code and lower resultsChapter 4 + LH-TK-04: recovery by fractions, discard volume from the window entered, comparison of filter lots, receipt check with the supplier's change notification. This is Case A.
A pipette outside its criterion at the intermediate checkChapter 9 + LH-TK-07 and LH-TK-08: segregation and label, deviation record, period to examine, list of preparations from LH-TK-01, start of the impact assessment. This is Case B.
A liquid handler program changed without change controlChapter 12 + LH-TK-10 and LH-TK-09: audit trail, gravimetric test per channel and per program version, approved programs and change rules. This is Case C.
A replaced rotor or a different centrifuge for the same methodChapters 13 and 14 + LH-TK-11 and LH-TK-12: prescribed RCF with the reference radius, rpm recalculated per rotor, check of runs, rotor register. This is Case D.
A reference standard to be weighed in a few milligramsChapters 17 and 18 + LH-TK-14 and LH-TK-15: repeatability test at the place of use, minimum weight for use with the chosen safety factor, net mass check, second check. This is Case E.
A new dilution chain or a calculation to reviewChapter 2 + LH-TK-02: overall factor, error propagation with correlation when the same pipette recurs over several steps, plausibility check, gravimetric check of one step.
A method that says to sonicate or shake "until dissolved"Chapters 15 and 16 + LH-TK-13: explicit parameters, final temperature measured against the limit entered, position in the bath, volume made up to the mark.
An inspection with sample preparation in scopeChapters 1, 9 and 18 + LH-TK-01, LH-TK-07 and LH-TK-16: contemporaneous records, statuses and due dates, balance in-use checks and trends, 109 inspector questions and 161 checklist rows built for training.
What the guide does not do

It gives no universal numbers. No universal values for pipette, dispenser and burette tolerances, check frequencies, replicates, discard volumes, centrifugation or sonication times, maintenance intervals, rotor life or minimum weights. Where a source states a value, the guide reports it with document, clause, nature and context; numerical examples are marked [DEMONSTRATION EXAMPLE].

It never declares an instrument fit or a result valid. No tool in the toolkit returns a favourable outcome: the only outcomes are "Comparison with the entered criteria" or "Assessment required", and missing data always lead to the latter. The decision on a result, an instrument, a batch or an investigation rests with the quality function, on the basis of data and a documented assessment.

It does not duplicate calibration or the sister guides. Operating technique and calibration: connected, not duplicated. The calibration programme, uncertainty, decision rules, intervals and retrospective impact assessment are in "Validation Manager and Calibration Manager — Operational Guide to Governing Validation and Running the Calibration Programme in the Pharmaceutical Industry (Second Edition + Toolkit)"; analytical instrument qualification and Karl Fischer titration in the "Operational Guide to Analytical Instrumentation in the GMP QC Laboratory (First Edition + Toolkit)"; data integrity governance, audit trails and electronic records in "Data Integrity in GMP – Operational Guide to Governance, Audit Trail Review and QC Laboratories"; validation of liquid handler software and other computerised systems in the "Operational Guide to Computer System Validation (CSV) in the GxP Environment"; investigation of OOS results and deviations, root cause analysis and CAPA in "Deviations, self-inspections and CAPA: the chain that holds up in inspection"; the requirements of pharmacopoeial chapters in "Pharmacopoeias in GMP – Operational Guide to USP, Ph. Eur., JP and BP (First Edition + Toolkit)"; validation and development of analytical procedures in "ICH Q Quality Guidelines: what is actually applicable, and readiness for the new Q1"; the preparation of microbiological samples in the "Operational Guide to the GMP Microbiology Laboratory and Sterility Testing (First Edition + Toolkit)". This guide covers the user side and how it connects to those requirements.

It is not legal advice and does not reproduce subscription texts. It describes the texts, status and force of the sources. ISO 8655, ISO 23783, ISO 4787, IEC 61010-2-020, USP–NF and Ph. Eur. are cited by title, number, edition and status, with no content, tables or numerical criteria: no maximum permissible error, tolerance or minimum weight criterion is reproduced, and instruments and consumables are never named by brand.

Contents: five parts, 18 chapters

Chapter titles of the English edition. Every chapter closes with inspector questions, an operational checklist, toolkit tools, hub articles, decision codes and the chapter's sources.

Part I — Preparation, Dilution & Filtration
  1. 1. Regulatory basis, responsibilities and GMP workflow of sample preparation: traceability, records, labels, expiry of prepared solutions and samples
  2. 2. Serial dilutions: calculations, choice of glassware and pipettes, error propagation and control of mistakes
  3. 3. Sample extraction: recovery, matrix, reproducibility; preparation as part of the validated method
  4. 4. Filtration, concentration and evaporation: syringe filters, adsorption and discard volume, losses and recovery
Part II — Pipettes & Pipetting Technique
  1. 5. Choosing the pipette: air or positive displacement, range, URS
  2. 6. Pipetting technique: forward, reverse, challenging liquids and error factors
  3. 7. Multichannel and electronic pipettes: channel uniformity, programs, settings and checks
  4. 8. Pipette tips: compatibility, retention, contamination and selection
  5. 9. Managing the pipette fleet: inventory, status, due dates, cleaning, maintenance, in-use and post-service checks, user-side out-of-tolerance handling
Part III — Dispensing & Automated Handling
  1. 10. Bottle-top dispensers: selection, chemical compatibility and verification
  2. 11. Manual and digital burettes: set-up, titration and operational checks
  3. 12. Automated liquid handling: URS, selection, qualification, programs and volumetric checks
Part IV — Centrifugation & Mixing
  1. 13. Laboratory centrifuges: selection, rotors, RPM and RCF
  2. 14. Centrifuge qualification and maintenance: speed, temperature, time, vibration, rotors and faults
  3. 15. Mixing: vortex mixers, orbital shakers and homogenisers
  4. 16. Sonication: bath or probe, temperature and reproducibility
Part V — Weighing & Balance Selection
  1. 17. Choosing and installing the analytical balance: capacity, resolution, minimum weight as a use requirement, environment
  2. 18. Analytical weighing: technique, static electricity, sample transfer and in-use checks

Appendices A–F. A ITA/ENG glossary · B Source matrix · C Chapter, toolkit and article matrix · D Toolkit instructions · E Register of assumptions and limitations · F Revision and change log.

What the package contains

After payment you download a ZIP file with the guide and the toolkit in the language of the chosen variant.

  • The complete PDF guide. 179 A4 pages in the Italian edition, 184 in the English one; clickable table of contents and bookmarks.
  • 16 editable tools. 10 Excel workbooks and 6 Word templates, in the folders 01_Preparation_Dilution_Filtration…05_Weighing.
  • 16 filled-in example copies. The same tools filled in with the Melvardi Pharma demonstration data, in the 06_Examples folder.
  • Support files. Toolkit instructions in PDF, toolkit index, chapter–toolkit–article matrix and a manifest with the SHA-256 hash of every file, in the 00_Read_Me folder.
  • Verification. Test Log and language parity report, in the 07_Verification folder.

Read the excerpt before you buy

The free excerpt is made of real pages: 16 pages in the Italian edition, 16 in the English one. It contains the presentation with the source status box and the labels, the full table of contents, from Chapter 13 RPM and RCF, reference radius and rotors, the complete Case D from Chapter 14, from Chapter 17 minimum weight as a use requirement, real pages of four tools (LH-TK-09, LH-TK-11, LH-TK-14 and LH-TK-15) and the list of what the purchase includes.

Specifications

FormatA4 PDF with clickable table of contents and bookmarks; tools in .docx and .xlsx
Pages and chapters179 pages (ITA edition) · 184 pages (ENG edition) · 18 chapters in five parts + 6 appendices (A–F)
Toolkit16 editable tools: 6 Word + 10 Excel, codes LH-TK-01…16, plus 16 filled-in example copies
File languagesOne language per purchase: ITA - Italiano or ENG - English. There are no files in French, German or Spanish.
Edition and revisionFirst edition, November 2026 · v1.0 · tools rev. 1.0
Regulatory verification21/11/2026 (status of every source as of that date)
ReferencesEU (EudraLex, EMA) · PIC/S · ICH · WHO · United Kingdom (HMR 2012, MHRA) · USA (21 CFR, FDA guidance) · OMCL Network (EDQM) · EURAMET, DKD, VIM and GUM · OIML and legal metrology · Ph. Eur., USP–NF, ISO and IEC standards (texts not reproduced)
Sources and decisions90 sources in the Appendix B matrix · 106 decisions in the Appendix E register
Free excerpt16 pages (ITA edition) · 16 pages (ENG edition)
UpdatesWhen the texts change, you receive the revised guide and toolkit at no extra cost.
DeliveryDigital product: download of the ZIP file after payment. No shipping: the 3D image of the volume is a graphic rendering; there is no printed book.
Software requirementsA PDF reader; Microsoft Word; Excel 2016 or LibreOffice 7: the Excel workbooks were recalculated with LibreOffice in the Test Log runs. No macros, no external links; calculated cells protected without a password.
LicenceIndividual use and internal use within the purchasing company: a personal, non-exclusive, non-transferable licence under the site's Legal Notice; printing for internal use only; sharing the files with third parties is prohibited.
Price€179.00 per variant (guide + toolkit in the chosen language)
Limits of use
  • The Excel workbooks are calculation templates with specification, tests and limits, not validated software: before GMP use, the laboratory verifies them in its own quality system by repeating the relevant cases of the TEST sheet.
  • Simulated case: Melvardi Pharma S.r.l. is a fictitious company; its site, laboratory, equipment, methods, people, suppliers, dates, events and figures are hypothetical. Every Melvardi value is a demonstration choice, not a recommended value or an acceptance criterion.
  • No sheet declares an instrument fit or a result valid: the only outcomes are "Comparison with the entered criteria" or "Assessment required". The guide does not replace the assessment of the quality function and does not decide what happens to a batch.
  • The guide does not replace the official texts cited and is not personalised legal, regulatory or quality advice. It names no brands or manufacturers of pipettes, tips, balances, centrifuges or liquid handlers: manufacturer's data stay in the laboratory's records.
  • The inspector questions are built for training; the FDA Warning Letters cited are real, anonymised and each illustrates one topic, with no statistical value. No guarantee of audit or inspection outcomes, which depend on context and application.
  • The numerical examples come from reproducible calculation scripts and are marked [DEMONSTRATION EXAMPLE]; the guide and the toolkit have not undergone independent third-party validation.

Who it is for. Senior analysts and QC laboratory supervisors, QC managers and method owners, laboratory QA, metrology and qualification leads, key users of liquid handlers and electronic pipettes, internal auditors and consultants preparing a laboratory inspection by AIFA, MHRA or FDA. It is written for those who prepare samples and solutions and use and govern liquid handling and weighing instruments and have to defend these choices in front of an inspector: knowing what each source requires, with what force, what it leaves open and how to write down the decision the source leaves to the laboratory.

Who it is not for. It is not an instrument user manual, a metrology textbook or a collection of ready-made values. It is not a guide to calibration (programme, uncertainty, intervals, retrospective impact), to analytical instrument qualification, to computerised system validation, to data governance or to OOS investigation (the subjects of the sister guides linked on this page). Out of scope: legal metrology of balances beyond the distinction from the GMP regime, electrical and mechanical safety of centrifuges, chemical safety in the laboratory, stability studies and the retention of reserve samples; the preparation of microbiological samples is cited only as an interface.

Frequently asked questions

Which language are the files in?

The language of the chosen variant: ITA - Italiano or ENG - English. Each purchase includes the guide and the toolkit in one language. There are no files in French, German or Spanish.

Is it a printed book?

No. It is a digital product: after payment you download a ZIP file with the PDF and the tools. No shipping; the 3D image is only a rendering of the volume.

Does the guide give pipette tolerances, check frequencies or minimum weights that apply to everyone?

No, because no GMP source read sets them. It reports the values the sources state, with their nature (the five pre-wetting cycles and the ten values per volume of DKD-R 8-1 are calibration rules; the OMCL Network's example frequencies remain examples; the safety factor for the minimum weight is chosen by the user), and the method for deciding the laboratory's own, each with its decision code (Chapters 6, 9 and 17).

Do the tools say whether a pipette is fit or a result is valid?

No. They return only "Comparison with the entered criteria" or "Assessment required"; missing data, criteria not entered or entries outside the list always lead to the latter, with the reason. The decision rests with the quality function.

Does it reproduce ISO 8655 or USP and Ph. Eur. criteria?

No. ISO and IEC standards and pharmacopoeial texts are sold by subscription: the guide reports their number, title, edition and status and describes the structure of the decision. Ph. Eur. chapter 2.1.7 on balances for analytical purposes, revised in Issue 13.1, applies from 01/01/2027: the guide does not reproduce its criteria, which are read in the current text.

Does it cover the calibration of pipettes and balances?

Only as an interface. The guide covers selection, use and in-use checks up to the user-side handling of an out-of-tolerance result (segregation, communication, start of the impact assessment). Calibration methodology, uncertainty, decision rules, intervals and retrospective impact are in the Validation Manager and Calibration Manager sister guide linked on this page.

Is a balance verified for legal metrology also calibrated?

No. Legal metrology, GMP calibration and in-use checks are three distinct regimes and none replaces the others: conformity when put into service is a requirement on the product, not on GMP use, and the periodicity of legal verification is not a calibration interval (Chapter 17).

Does it apply to the United States and the United Kingdom?

The main reference is the EU, with PIC/S as guidance and WHO as a secondary source. For the United States the guide covers 21 CFR 211 (in particular 211.68, 211.160 and 211.194), the FDA guidance on data integrity, OOS results and validation of analytical procedures, and the CGMP Q&As; the 1993 FDA guide to inspections of QC laboratories is reference material for investigators, not binding. For the United Kingdom it covers the Human Medicines Regulations 2012 and the MHRA data integrity guidance.

Are the Excel workbooks validated?

They are not validated software. Each one has a README sheet with purpose and instructions, readable formulas, error checks and a TEST sheet with the test cases and their result: the laboratory verifies them in its own system before GMP use.

What happens when the reference texts change?

Appendix F lists the events that trigger re-verification of the guide: applicability of Ph. Eur. 13.1 and 13.2, new USP–NF Issues, final texts of the EU drafts, the draft of Annex 15, the revisions of OIML R 76 and of Chapter 3. When the texts change, you receive the revised guide and toolkit at no extra cost. The revision on sale is shown on this page, with the regulatory verification date.

Can I share the files with colleagues or an external provider?

The licence is for individual use and internal use within the purchasing company, personal, non-exclusive and non-transferable: sharing the files with third parties, including calibration and maintenance service providers and external consultants, is prohibited. Printing is allowed for internal use only.

Before you buy: the Liquid Handling & Sample Preparation hub

The 24 technical articles of the hub introduce the five themes of the guide, from sample preparation and dilution to the selection of an analytical balance.

Go to the Liquid Handling & Sample Preparation hub →
Do you have a pipette outside its criterion, a filter that retains the analyte or a minimum weight to justify?
Describe the instrument or the preparation, the stage (selection, qualification, routine use or investigation) and where you are stuck. GuideGxP will review the request and, where appropriate, may put you in touch with a specialist suited to your technical needs and your geographical area.
Describe your situation →
No purchase obligation. The request is reviewed before any referral to a specialist.

GuideGxP guides do not replace official legislation or the guidance and standards cited (European Commission, EMA, PIC/S, ICH, WHO, FDA, MHRA, EDQM, EURAMET, OIML, ISO, IEC, USP): they are operational support tools, do not constitute legal advice, and users remain responsible for the correct application of the rules in force in their own company context. Subscription texts are not reproduced. Numerical examples are for demonstration and are not acceptance criteria; the decision on the validity of a result and on what happens to a batch rests with the quality function. Regulatory status verified as of 21/11/2026. Melvardi Pharma S.r.l. is a fictitious company. Digital product: no physical shipping.

DECLARED REGULATORY BASIS

Built on the most up-to-date official sources.

Every guide is built from the official sources current at the editorial verification date stated in the document. The editions, revisions and cut-off dates used are declared and checked again for every new release; requirements are kept distinct from GuideGxP operational interpretation.

Main references for this guide EU GMP · ICH · PIC/S · FDA/EMA guidance applicable to the topic
  • Editions and revisions stated in the document
  • Explicit editorial verification date
  • Requirements separated from practical recommendations

GuideGxP is an independent publisher and is not affiliated with, approved by or sponsored by the authorities and organisations cited.

INCLUDED WITH YOUR PURCHASE

Every new release is delivered automatically by email.

Buy once: whenever we publish a new release of the guide you purchased, it is sent automatically to the email address used for the order, together with the download link. No request, new registration or additional payment is required.

  • Every future release included for life
  • Automatic delivery to the order email
  • Average review cycle: 6 months

Timing may vary with regulatory and technical developments. No action is required after purchase; simply use a valid email address at checkout.

A PRACTICAL PERSPECTIVE

Experiences with our guides and toolkits.

Perspectives on using GuideGxP guides and toolkits.

The editable files are the most useful part. I read the explanation in the guide, then work on the documents without starting from scratch.

Raphaela M.QA Specialist
Guides and toolkits

The templates need adapting to your site. But having a well-considered structure is very different from starting with a blank page.

Ramón María G.Validation Manager
Guides and toolkits

I wanted practical support, not another collection of definitions. The examples helped me connect the reading to the work we do in the laboratory.

Philippine M.QC Laboratory Manager
Guides and toolkits

I read the preview before buying. It helped me understand the guide’s approach and whether it covered what I was looking for.

Haraldur P.Quality Specialist
Guides and toolkits

I choose the templates the project needs and adapt them. For me, the benefit is having a consistent starting point.

Kael B.Validation Engineer
Guides and toolkits

I keep it as a reference while we review procedures. I can return to the topic I need without reading everything again from the beginning.

Isabella L.Quality Assurance Manager
Guides and toolkits

Explanation and tools in the same package: first I understand why an activity matters, then consider how to approach it in our context.

Napoléon L.Production Manager
Guides and toolkits

Some topics need careful reading, but I like the practical approach. It gave me useful ideas for reviewing how we organise our documentation.

Elwin L.Quality Systems Manager
Guides and toolkits

I wanted to understand how the topic translates into daily activities. I found a useful basis for discussing with QA what needed clarifying in our instructions.

Anne-Sophie M.Production Department Head
Guides and toolkits

I chose the guide after checking the included content. I like that the material is designed to be used and adapted, as well as read.

Andrea M.Compliance Specialist
Guides and toolkits

It helped align terminology across different functions. A shared outline makes it easier to discuss requirements, responsibilities and the documents to prepare.

Are Ø.Project Manager (Tech Transfer)
Guides and toolkits

I mainly use it to organise a topic before an internal discussion. The value is having explanations, references and tools within the same learning path.

Nik U.GMP Consultant
Guides and toolkits
Use the arrows, drag the cards or choose “Read all”.

Delivery & FAQs

Before you buy

A question before you buy?

Contact us
How do I receive my files?

After payment confirmation, download instructions are sent to the order email address. This is a digital product, with no physical shipping.

Is the guide in the website language?

The available editions are Italian and English. Select the file language before adding the product to your cart.

Are updates included?

Future releases of your purchased guide are included and sent to the order email address. Timing depends on regulatory and technical developments.

Can I adapt the templates to my quality system?

Where Word and Excel files are included, you can adapt them to your context. The contents require professional judgement and do not replace official regulations.